Limit of quantification (LOQ)
LOQ, the limit of quantification, is the smallest amount a lab method can measure reliably; a not-detected result shows compliance only if the LOQ is at or below the limit.
The limit of quantification (LOQ) is the smallest amount of a substance that a laboratory's method can measure with acceptable accuracy and precision. Below it, the laboratory reports the substance as not detected, or as less than the LOQ (for example, less than 0.01 mg/kg).
How it works
- Every method has its own LOQ for each substance and product. A multi-residue pesticide method may reach 0.01 mg/kg for most substances but not for all.
- The limit of detection (LOD) is lower still: the level at which a substance can be seen to be present but not reliably measured.
- When a destination's limit is set at the LOQ, as many EU MRLs are, the laboratory must reach at least that LOQ for its result to mean anything.
Why it matters
Not detected only means the substance was below what that method could measure. If the method's LOQ is above the destination's limit, the lot could hold more than the limit and still be reported as not detected. A buyer, a bank or a border authority reading that report learns nothing about compliance.
Example
The EU limit for aflatoxin B1 in sesame placed on the market as is, or used as an ingredient, is 2.0 µg/kg.
- Report A: aflatoxin B1 not detected, LOQ 0.5 µg/kg. The LOQ is below the limit, so the result shows the lot is within it.
- Report B: aflatoxin B1 not detected, LOQ 5 µg/kg. The lot could contain up to 5 µg/kg without it being detected, so the result cannot show it is within 2.0. Ask the laboratory to re-test with a method that reaches below the limit.
Good to know
- Agree the LOQ with the laboratory before testing, in the unit of the destination's limit.
- Some limits are on a sum, such as total aflatoxins, and the EU counts results below the LOQ as zero when adding them up. Check how the limit is defined.
Questions
What is LOQ?
LOQ, the limit of quantification, is the smallest amount a lab method can measure reliably; a not-detected result shows compliance only if the LOQ is at or below the limit. The limit of quantification (LOQ) is the smallest amount of a substance that a laboratory's method can measure with acceptable accuracy and precision. Below it, the laboratory reports the substance as not detected, or as less than the LOQ (for example, less than 0.01 mg/kg).
What is the difference between the LOQ and the LOD?
The LOD is the lowest level at which a method can tell a substance is present; the LOQ is the lowest level it can measure reliably. Compliance is judged on the LOQ.
Does not detected mean zero?
No. It means below the method's limit of quantification. It shows compliance only when that LOQ is at or below the destination's limit.
Related terms
Sources
- European Commission, EU Pesticides Database food.ec.europa.eu/plants/pesticides/eu-pesticides-database_en
- Commission Regulation (EU) 2023/915, consolidated (EUR-Lex) eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:02023R0915-20260819
Rules, rates and lists change. Nohena applies the version in force on the date of each check; confirm the current text with the body that owns it.