Lab results and the limit of quantification
Enter each lab report on the Lab results tab. A not-detected result shows a lot is within a limit only when the laboratory's limit of quantification (LOQ) is at or below it.
Enter each lab report on the export's Lab results tab, and Nohena checks every value against the destination's limit. A result reported as not detected shows the lot is within a limit only when the laboratory's limit of quantification (LOQ) is at or below that limit.
How to enter a lab result
- Open Lab results and select Enter a lab result.
- Enter the Laboratory, the Report number and the Report date, and choose the Lot it covers, or The whole shipment.
- Tick The laboratory is accredited to ISO/IEC 17025 for these tests only if the report says so.
- For each substance, pick it from the list (the EU pesticide list and the contaminants the check reads for your goods) or type it. Enter the Value and the Unit: mg/kg, µg/kg or µg/kg fat.
- For a substance the laboratory did not detect, tick Not detected and enter the LOQ in the same unit.
- Use Add a substance for each further result, then select Save and check. The destination rules run again.
You can also add the report on the Documents tab. Nohena reads it, and you choose Add the lab results.
What Nohena checks
- Each value against its limit, converted to the limit's unit.
- Not detected with an LOQ above the limit is to fix: the result cannot show the lot is within the limit, so ask the laboratory to test to a lower limit.
- A value with no usable unit is to fix: check the report.
- With several lots tested, the worst result counts for the shipment.
- For the EU's increased Salmonella checks on Nigerian sesame: an accredited laboratory, and a result no more than six months old at shipping.
Good to know
If you leave the LOQ blank, a not-detected result is read as within the limit, so enter it whenever the report states one. Nohena records the accreditation you tick or the report states; it does not verify it. A result from a laboratory not recorded as accredited shows NOT ACCREDITED.
Questions
Why does Nohena ask for the LOQ?
Not detected only means the substance was below what the laboratory could measure. If that level is above the limit, the result cannot show the lot meets the limit.
Can one lab report cover the whole shipment?
Yes. Choose The whole shipment as the lot it covers. If your export has lots that were tested one by one, bind each report to its lot so a lot with no result of its own is flagged.
Does Nohena check the laboratory's accreditation?
No. It records what you tick or what the report states. Where an accredited laboratory is required, a result not recorded as accredited is flagged.
Quick answers
- How do I withdraw a lab result entered by mistake?
- How does Nohena record accreditation from a lab report it read?
- Should I pick a substance from the list or type it in a lab result?
- What does Not applied, enter by hand mean after applying a lab report?
- What does the laboratory's limit of quantification is above the limit mean?
- Why is a lab result shown as Unclear?
- Why is my export still blocked after a re-test came back within the limit?
- Why won't my lab result save?