What does the laboratory's limit of quantification is above the limit mean?
The substance was not detected, but the laboratory could not measure down to the limit, so the result cannot show the lot is within it; ask for a method with a lower LOQ.
The finding Not detected, but the laboratory's limit of quantification (...) is above the limit of (...), so the result cannot show the lot is within it. Ask the laboratory to test to a lower limit. means the method could measure only down to the LOQ. Below that, the substance could be present above the limit without being detected. The item is TO FIX, with Found shown as Not detected.
What to do
Ask the laboratory, before it tests, for a method whose LOQ is at or below the destination's limit. Reports on an export are never replaced, so a finding like this stays on the export's record.
Good to know
- Nohena converts the LOQ to the limit's unit before comparing, so enter it in the same unit as the value on that row.
- If you leave the LOQ blank, a not-detected result is read as within the limit. Enter it whenever the report states one.
- The same check applies to EU pesticide and contaminant limits, the reviewed product rules and Japan's residue limits.