Nohena Insights · Commodities
What not detected means on a sesame lab report
On a laboratory report for sesame, 'not detected' means a substance was not found above the test's limit of quantification. It does not mean zero, a key fact for meeting destination MRLs.
Nohena · 20 November 2026 · 8 min read

What does 'not detected' mean on a laboratory report?
On a laboratory report for sesame, 'not detected' means a substance was not found at or above the minimum concentration the test method can reliably measure, known as the limit of quantification. It does not mean the substance is completely absent, a critical distinction for Nigerian exporters who must prove their goods meet the strict legal limits of destination markets.
For exporters of Nigerian sesame , a laboratory report is not just a piece of paper; it is a passport for market access. A result of 'not detected' for a pesticide or mycotoxin can feel like a victory. However, the true meaning of this result lies in the technical details of the test itself. Understanding these details is fundamental to managing risk, preventing costly rejections at the border, and building a reputation for quality. It is a core part of getting the export right before it is checked.
The difference between zero and not detected
The difference between zero and 'not detected' is that zero implies the absolute absence of a substance, while 'not detected' signifies its concentration is below the laboratory's measurement threshold.
No analytical instrument, no matter how advanced, can detect an infinitely small amount of a chemical. Every test has a sensitivity limit. This reality is defined by two key terms that every exporter should know:
Limit of Detection (LOD) : This is the lowest concentration at which an instrument can signal that a substance is present. At the LOD, the lab can say, 'something is there', but it cannot confidently state how much. It is a qualitative, not quantitative, signal.
Limit of Quantification (LOQ) : This is the lowest concentration of a substance that a laboratory can measure with an acceptable and stated degree of precision and accuracy. The LOQ is the number that matters for trade compliance. It is the minimum level at which the lab can confidently report a specific numerical value.
Think of it like a vehicle weighbridge. If the bridge is only certified to measure in increments of 10 kilograms, a 3-kilogram bag of sesame seeds placed on it would register as 0 kg. The bag is not weightless; its weight is simply below the bridge's limit of quantification. A laboratory report stating 'not detected' for a pesticide is making a similar claim: if the substance is present, it is at a level below what the method can reliably quantify.
Reputable laboratories, particularly those with ISO/IEC 17025 accreditation, will always specify the LOQ for each substance tested directly on the report. A result of 'Not Detected <0.005 mg/kg' is a precise, defensible statement. A result that simply says 'ND' with no stated limit is ambiguous and insufficient for demonstrating due diligence to a discerning buyer or a foreign regulator.
Why the LOQ matters for sesame exports
The limit of quantification (LOQ) is critical for sesame exports because it must be lower than the maximum residue limit (MRL) set by the destination country to provide valid proof of compliance.
Destination markets, especially sophisticated ones like the European Union, Japan, and the United States, do not leave food safety to chance. They codify precise legal limits for contaminants.
Meeting the EU's maximum residue limits
The European Union maintains a comprehensive, publicly available MRL database for pesticides in food products. For every combination of pesticide and product (like sesame seeds), a specific MRL is established. If a particular pesticide does not have a specific limit for sesame, a default MRL of 0.01 milligrams per kilogram (mg/kg) often applies. This is an extremely low concentration.
Here is the critical connection:
The Law : The EU MRL for 'Pesticide X' on sesame is 0.05 mg/kg.
The Test : You send your sesame sample to a lab for testing.
The Compliance Check : To prove your sesame meets the 0.05 mg/kg limit, your lab's LOQ for 'Pesticide X' must be *below* 0.05 mg/kg. An LOQ of 0.01 mg/kg or 0.005 mg/kg would be appropriate.
If the lab's LOQ is 0.1 mg/kg (higher than the MRL), a 'not detected' result is meaningless for compliance. The sesame could contain the pesticide at a concentration of 0.08 mg/kg, which is illegal in the EU but still below the lab's ability to quantify. A border control authority in the EU would rightfully reject such a lab report as inconclusive. This can lead to the consignment being flagged on the Rapid Alert System for Food and Feed (RASFF), causing reputational damage and triggering increased scrutiny on future shipments from Nigeria under regulations like (EU) 2019/1793.
Beyond pesticides: Mycotoxins and other contaminants
The same principle applies to other regulated contaminants, such as mycotoxins (e.g., aflatoxins). EU Regulation (EU) 2023/915 sets maximum levels for certain contaminants in foodstuffs. For sesame seeds intended for direct human consumption, there are specific, low-level limits for aflatoxin B1 and total aflatoxins. Your lab report must demonstrate, through a sufficiently low LOQ, that your product is compliant with these non-negotiable food safety standards.
How to choose a laboratory for your sesame testing
Choose an accredited laboratory that can demonstrate its testing methods achieve a limit of quantification (LOQ) below the specific MRLs of your target destination market.
Your choice of laboratory is a critical risk management decision. Not all labs are created equal. Use the following criteria to vet a potential testing partner:
From lab report to export-ready documents
A compliant lab report is a critical component of the export documentation package that must be consistent with the commercial invoice, packing list, and Nigerian export requirements.
The lab report does not exist in isolation. It is a key piece of evidence that supports the declarations you make on other mandatory documents. In Nigeria, the export process requires careful coordination of several elements:
The Contract : Your sales contract specifies the quality, including limits for residues and contaminants. Your lab report proves you have met these terms.
Nigerian Export Formalities : The data from your commercial documents and certificates is used to complete the Form NXP (Nigerian Export Proceeds Form) via the CBN's Trade Monitoring System. This process also involves the Nigeria Agricultural Quarantine Service (NAQS), which issues the phytosanitary certificate, and potentially the Federal Produce Inspection Service (FPIS) for grading. All documents must align.
The NESS Levy : A levy of 0.5% of the Free on Board (FOB) value is payable to the Nigeria Export Supervision Scheme.
Proceeds Repatriation : As per the CBN's Foreign Exchange Manual, proceeds from non-oil exports must be repatriated to Nigeria within 180 days of shipment. A compliant consignment that is paid for on time completes this cycle.
This is where decision support becomes invaluable. The Nohena export desk checks the complete document set, lot by lot. It verifies that the lab report is valid for the destination, that its LOQs are sufficient, and that the quantities and descriptions match the invoice, packing list, and Form NXP. This check prepares a consistent, lodgement-ready pack for the exporter or their licensed agent to file, confident that the details are right before they are checked by Nigerian authorities or the destination's border control.
This verified record can also, with the exporter's consent, be shared with a financier to support a request for trade finance. A detailed, compliant history builds the confidence a lender at an institution like NEXIM or Afreximbank needs to see before financing a transaction. Nohena shares the consented, read-only record; the financier decides.
Ultimately, a deep understanding of your lab report is about more than just compliance. It is about controlling your export outcome. Explore more analysis on our insights page or see how Nohena prepares your exports for the destination. For a detailed walkthrough, you can request a demo of the export desk.
FAQ
What is the difference between LOD and LOQ?
The Limit of Detection (LOD) is the smallest amount of a substance a test can signal is present, while the Limit of Quantification (LOQ) is the smallest amount it can measure accurately and reliably. For international trade compliance, the LOQ is the important figure because it provides a quantitative result that can be compared to a legal limit.
What is the default MRL for pesticides in the EU?
The European Union applies a default Maximum Residue Limit (MRL) of 0.01 milligrams per kilogram (mg/kg) for pesticide residues in or on food and feed for which no specific MRL has been set. This is a very low, precautionary limit.
Why does my lab need ISO/IEC 17025 accreditation?
ISO/IEC 17025 accreditation is the international standard confirming the technical competence of a testing laboratory. It demonstrates that the lab's quality management system and testing methods are sound and produce reliable results, which is often a requirement for the lab report to be accepted by international buyers and regulatory authorities.
Can a 'not detected' result still lead to a rejection at the border?
Yes, a 'not detected' result can lead to rejection if the laboratory's limit of quantification (LOQ) for the test was higher than the destination country's legal limit (MRL). The report must prove the test was sensitive enough to detect a violation if one existed. A 'not detected' result from an insufficiently sensitive test is inconclusive.